VersaCoat Flowable Hydrogel* is a hyaluronic acid-based soft-tissue protection device cleared for tendon, ligament, skeletal muscle, and peripheral nerve applications.
Engineered for precision delivery, VersaCoat Flowable Hydrogel forms a tissue-adherent gel layer that stays where applied and delivers a sustained gliding surface between adjacent tissue planes, preventing postoperative tethering and supporting natural tissue mobility. VersaCoat Flowable Hydrogel fully bioresorbs throughout healing, leaving only the body’s natural tissues behind.
VersaCoat Flowable Hydrogel is ideal for complex or difficult-to-access anatomical sites where minimal tissue manipulation and controlled placement are desired, such as tight openings, multi-site repair, minimally invasive approaches, or tissues that are already approximated.
Ready to use and syringe-deliverable, VersaCoat Flowable Hydrogel gives surgeons the confidence to provide their patients an optimized recovery.
Simple Preparation. Precise Delivery.
- Syringe-deliverable gel
- Discrete aliquots
- Precise, controlled placement within complex or
difficult-to-access anatomical sites - Tight openings
- Minimally invasive approaches
Rapid, Intuitive Preparation
Dry biopolymer pellet to syringe-deliverable gel in under one minute. Easy to prepare. No waiting.
Immediate Application. No Set Time.
Ready to apply the moment preparation is complete. VersaCoat Flowable Hydrogel functions on contact with tissue, requiring no cure time or delay before closure
Stays Where Applied
Delivered gel forms a tissue-adherent layer that stays where applied, providing a sustained gliding surface throughout the critical healing period
Composition
VersaCoat Flowable Hydrogel is built on VersaCore Hydrogel Technology, the proprietary, naturally-derived biopolymer platform behind our soft-tissue protection portfolio. This bioresorbable composition provides a permeable, non-constricting gliding interface between target tissues and surrounding structures
Hyaluronic Acid (HA)
Hyaluronic Acid (HA)
- Known anti-inflammatory1
- Recruited to injury site, critical to healing1
- Immobilizes water on its surface, preventing cellular adhesion, facilitating gliding, movement, and debris removal
Engineered to Prevent Tethering
and Optimize Healing
Soft-tissue protection requires more than a physical barrier. VersaCore Hydrogel Technology combines distinct material properties that work together to prevent tethering, support natural healing, and leave only the body’s own tissues behind
Prevents Tethering
Prevents Tethering
- Provides protective gliding surface
- Negative charge naturally repels cellular attachment
Conformable
Conformable
- Conforms to tissue and implanted structures
- Ultrathin profile
- Non-swelling
- Non-constricting
Stays Where Applied
Stays Where Applied
- Mucoadhesive
- Sutureless
- Does not migrate
Selectively Permeable
Selectively Permeable
- Limits infiltration of proteins and cells
- Permits exchange of oxygen, nutrients, and small molecules (e.g., growth factors)
Bioresorbs Completely
Bioresorbs Completely
- Bioresorbs as part of the natural healing process
- Alternative to collagen-based materials that may remodel and add bulk
Biocompatible
Biocompatible
- No human or animal tissue
- Elicits little to no immune response
- Non-neurotoxic
- No tissue tracking requirements
Tissue Tracking NOT Required
Tissue Tracking NOT Required
- Suitable for patients with known cultural or physiological sensitivities to animal or human tissue products
Unparalleled Protection
One portfolio. Complete coverage. VersaCoat Flowable Hydrogel is cleared to protect tendons, ligaments, and skeletal muscles, and to manage peripheral nerves and the neural environment, across all age groups. VersaCoat Flowable Hydrogel may be placed adjacent to implants, hardware, and grafts, giving surgeons the confidence to protect every structure in the surgical field.

Tendon

Ligament

Muscle

Peripheral
Nerve

Nerve Root

Adjacent to Implants
Cleared for Use Across All Ages
| Part Number | Product Type | Size |
|---|---|---|
| VTP-12G1 | VersaCoat Flowable Hydrogel | 1 mL |
| VTP-44G2 | VersaCoat Flowable Hydrogel | 2 mL |
*VersaCoat™ Flowable Hydrogel is a single product regulated as VersaCoat™ Tendon Protector and VersaCoat™ Nerve Protector
References 1.Kawano Y, Patrulea V, Sublet E, Borchard G, Iyoda T, Kageyama R, and Hanawa T. (2021) Wound healing promotion by hyaluronic acid: Effect of molecular weight on gene expression and in vivo wound closure. Pharmaceuticals,14(4), 301. https://doi.org/10.3390/ph14040301;
2. Hirt N., et al. (2025). A novel calcium alginate hydrogel formulation to enhance monocyte/ macrophage anti-inflammatory activity. International Journal of Biological Macromolecules, 306. https://doi.org/10.1016/j.ijbiomac.2025.141251
3. Data on file, Alafair Biosciences
Always refer to the complete instructions for use for the complete clinical instructions.
This content is for informational purposes only and is not intended to constitute medical advice. As with any medical device, there are multiple factors affecting patient outcomes, including post-operative recovery time and activity level. Patient outcomes may vary based upon, among other factors, the nature and extent of loss or damage, the time between injury or damage and surgery, and the natural course of the patient’s recovery.
The availability of these products is in the United States only. Warning: Applicable laws restrict these products to sale by or on the order of a physician.